FL18582.3-R2

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:

Flush Glazed Fiberglass Door

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

8'-0" Inswing Single or Double Door w/ or w/o Sidelites

Listing Details
Category:
Doors
Subcategory:
Swinging Exterior Door Assemblies
Evaluator:
  -  
Validator:
National Accreditation & Management Institute
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
National Accreditation & Management Institute
Specifications
Submission Date:
December 2, 2017
Validation Date:
December 7, 2017
Expiration Date:
12/31/2021
HVHZ Approved:
Yes
Impact Resistant:
No [FL]
Design Pressures:
-47psf / +45psf
Possible CSI Codes:
CSI Code: 08 36 16 - Single-Panel Doors
CSI Code: 08 17 00 - Integrated Door Opening Assemblies
CSI Code: 08 13 13.13 - Standard Hollow Metal Doors
CSI Code: 06 48 13 - Exterior Wood Door Frames
CSI Code: 08 42 36 - Balanced Door Entrances
Other:
Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system required in HVHZ and the Wind Borne Debris Region. See DWG-MA-FL0183-15 for additional information.
Notes:


Date Submitted: December 2, 2017

Date Validated: December 7, 2017

Entity: National Accreditation & Management Institute

Compliance Method: Certification Mark or Listing

Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, does not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system required in HVHZ and the Wind Borne Debris Region. See DWG-MA-FL0183-15 for additional information.

Official Site Status: Approved

Subcategory: Swinging Exterior Door Assemblies
Contact Information
Representative:
Steve Schreiber
Address:
1955 Powis Road,
West Chicago, Illinois 60185 US
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 07/26/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL18582 R2 C CAC NI012729.02
PR CERTIFICATE FL18582 R2 C CAC NI012729.02
PR INSTL DOCS FL18582 R2 II  FL0183
PR INSTL DOCS FL18582 R2 II FL0183
PR TECH DOCS FL18582 R2 AE 514007A
PR TECH DOCS FL18582 R2 AE 514007A
PR TECH DOCS FL18582 R2 AE 514011A
PR TECH DOCS FL18582 R2 AE 514011A
QR Code To This Listing
FL18582.3-R2 Listing QR Code