engineering plans logo black

FL19278.1-R7

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

SCV501MD Hurricane Louver

Database:
Florida Product Approval
Source Link:
Description:

5" Deep Vertical Blade Louver, Extruded Aluminum, High Velocity Wind Driven Rain Resistant, Impact & Pressure Resistant

Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Wall Louver
Evaluator:
Robert Nangia - PE-69555
Validator:
Locke Bowden P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
October 20, 2023
Validation Date:
April 24, 2024
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-130psf / +130psf
Possible CSI Codes:
CSI Code: 07 70 00 - Roof and Wall Specialties and Accessories
CSI Code: 08 91 16 - Operable Wall Louvers
CSI Code: 06 40 13 - Exterior Architectural Woodwork
CSI Code: 07 46 19 - Steel Siding
CSI Code: 06 20 13 - Exterior Finish Carpentry
Other:
Allowable Stress Design (ASD). Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Blades Fully Open. Substrates Include: Cracked Concrete, Grout Filled CMU, Steel, Aluminum & Wood.
Notes:


Date Submitted: October 20, 2023

Date Validated: April 24, 2024

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Allowable Stress Design (ASD). Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Blades Fully Open. Substrates Include: Cracked Concrete, Grout Filled CMU, Steel, Aluminum & Wood.

Official Site Status: Approved

Subcategory: Wall Louver
Contact Information
Representative:
Michael Steele
Address:
PO Box 410,
Schofield, Wisconsin 54476 United States
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/22/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL19278 R7 II FPA 19278 SCV501MD PE EVAL REPORT 2021-8-18
PR INSTL DOCS FL19278 R7 II FPA 19278 SCV501MD PE EVAL REPORT 2021-8-18
PR INSTL DOCS FL19278 R7 II FPA 19278 SCV501MD PE EVAL REPORT 2024-01-05
PR INSTL DOCS FL19278 R7 II FPA 19278 SCV501MD PE EVAL REPORT 2024-01-05
PR INSTL DOCS FL19278 R7 II TBD
PR INSTL DOCS FL19278 R7 II TBD
PR TECH DOCS FL19278 R7 AE FPA 19278 SCV501MD PE EVAL REPORT 2021-8-18
PR TECH DOCS FL19278 R7 AE FPA 19278 SCV501MD PE EVAL REPORT 2021-8-18
PR TECH DOCS FL19278 R7 AE FPA 19278 SCV501MD PE EVAL REPORT 2024-01-05
PR TECH DOCS FL19278 R7 AE FPA 19278 SCV501MD PE EVAL REPORT 2024-01-05
PR TECH DOCS FL19278 R7 AE TBD
PR TECH DOCS FL19278 R7 AE TBD

Your Ad on 100K+ Listings Contact Us
QR Code To This Listing
FL19278.1-R7 Listing QR Code
Shopping Cart