Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Structural steel lapped panel fastened into Steel Supports
Listing Details
Category:
Components, Fasteners, Materials
Subcategory:
Structural Wall
Evaluator:
James L. Buckner, P.E. @ CBUCK, Inc. - PE-31242
Validator:
Steven M. Urich, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
October 18, 2018
Validation Date:
October 18, 2018
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
No [FL]
Design Pressures:
-65.93psf / +52psf
Possible CSI Codes:
CSI Code: 05 12 00 - Structural Steel Framing
CSI Code: 07 42 13 - Metal Wall Panels
CSI Code: 06 12 00 - Structural Panels
CSI Code: 07 42 13.13 - Formed Metal Wall Panels
CSI Code: 07 42 13.16 - Metal Plate Wall Panels
Other:
Refer to evaluation report for conditions and limitations of use. Refer to manufacturer's installation instructions as supplemental guide for attachment.
Notes:
Date Submitted: October 18, 2018
Date Validated: October 18, 2018
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Refer to evaluation report for conditions and limitations of use. Refer to manufacturer's installation instructions as supplemental guide for attachment.
Official Site Status: Approved
Subcategory: Structural Wall
Contact Information
Representative:
Gary Bonacci
Address: