FL19665.2-R5

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

EHH-601DE Hurricane Louver (Flanged & Sleeved Frame)

Database:
Florida Product Approval
Source Link:
Description:

6" Deep Horizontal Blade Louver with Flanged & Sleeved Frame, Extruded Aluminum, Impact & Pressure Resistant with Option for High Velocity Wind Driven Rain Resistance

Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Wall Louver
Evaluator:
Robert Nangia - PE-69555
Validator:
Locke Bowden P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
October 19, 2023
Validation Date:
July 16, 2025
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-150psf / +150psf
Possible CSI Codes:
CSI Code: 08 91 16 - Operable Wall Louvers
CSI Code: 05 25 00 - Aluminum Joist Framing
CSI Code: 05 21 00 - Steel Joist Framing
CSI Code: 05 21 13 - Deep Longspan Steel Joist Framing
CSI Code: 48 15 13 - Wind Turbines
Other:
Allowable Stress Design (ASD). Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Fully Closed VCD-40 Damper. Substrates Include: All Types via Anchorless Flange Capture.
Notes:


Date Submitted: October 19, 2023

Date Validated: July 16, 2025

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Allowable Stress Design (ASD). Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Fully Closed VCD-40 Damper. Substrates Include: All Types via Anchorless Flange Capture.

Official Site Status: Approved

Subcategory: Wall Louver
Contact Information
Representative:
Michael Steele
Address:
1110 Greenheck Drive (PO Box 410),
Schofield, Wisconsin 54476-0410 United States
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information
Listing Changes
Last Synced: 06/06/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL19665 R5 II 19665 EHH-601DE PE EVAL REPORT 4-13-2021
PR INSTL DOCS FL19665 R5 II 19665 EHH-601DE PE EVAL REPORT 4-13-2021
PR INSTL DOCS FL19665 R5 II 19665 EHH-601DE PE EVAL REPORT 6-26-2025
PR INSTL DOCS FL19665 R5 II 19665 EHH-601DE PE EVAL REPORT 6-26-2025
PR INSTL DOCS FL19665 R5 II TBD
PR INSTL DOCS FL19665 R5 II TBD
PR TECH DOCS FL19665 R5 AE 19665 EHH-601DE PE EVAL REPORT 4-13-2021
PR TECH DOCS FL19665 R5 AE 19665 EHH-601DE PE EVAL REPORT 4-13-2021
PR TECH DOCS FL19665 R5 AE 19665 EHH-601DE PE EVAL REPORT 6-26-2025
PR TECH DOCS FL19665 R5 AE 19665 EHH-601DE PE EVAL REPORT 6-26-2025
PR TECH DOCS FL19665 R5 AE TBD
PR TECH DOCS FL19665 R5 AE TBD
QR Code To This Listing
FL19665.2-R5 Listing QR Code
Shopping Cart