FL20381.2-R2
Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Revision
Folio:
Model:
Formawall Dimension Series/Formawall Dimension Series Graphix 2-1/2T Panels
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Formawall Dimension Series/Formawall Dimension Series Graphix 2-1/2T Panels - 36" Module Size
Listing Details
Category:
Components, Fasteners, Materials
Subcategory:
Structural Wall
Evaluator:
Robert J Amoruso, P.E. - PE-49752
Validator:
Steven M. Urich, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
June 21, 2021
Validation Date:
June 24, 2021
Design Pressures:
-60psf / +60psf
Possible CSI Codes:
CSI Code: 06 12 00 - Structural Panels
CSI Code: 07 42 63 - Fabricated Wall Panel Assemblies
CSI Code: 26 24 16 - Panelboards
CSI Code: 07 42 00 - Wall Panels
CSI Code: 07 44 63 - Fabricated Faced Panel Assemblies
Other:
Notes:
Date Submitted: June 21, 2021
Date Validated: June 24, 2021
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other:
Official Site Status: Approved
Subcategory: Structural Wall
Contact Information
Representative:
Craig Storch
Address:
1550 Coraopolis Heights Road Suite 500,
Moon Township, Pennsylvania 15108 USA
Moon Township, Pennsylvania 15108 USA
Phone:
Website:
Listing Changes
Last Synced: 03/24/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL20381 R2 II INSTALL FWDS FWGS 36IN INSTALLATION DETAILS REV1 SS

PR TECH DOCS FL20381 R2 AE PER 2437 REV2 FWDS-FWGS-WALL PANEL SS
QR Code To This Listing