FL22537.1-R2

Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Affirmation
Folio:
Model:

Aluminum Clad Wood Out-Swing Vent & Fixed Casement Windows

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

Aluminum Clad Wood Out-Swing Vent & Fixed Casement Windows (Small & Large Missile Impact)

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Casement
Evaluator:
Warren W. Schaefer - PE-44135
Validator:
T.E. Lunn, PE, LLC
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
July 22, 2020
Validation Date:
July 22, 2020
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-70psf / +70psf
Possible CSI Codes:
CSI Code: 08 52 13 - Metal-Clad Wood Windows
CSI Code: 08 51 13 - Aluminum Windows
CSI Code: 08 52 16 - Plastic-Clad Wood Windows
CSI Code: 08 52 00 - Wood Windows
CSI Code: 08 52 69 - Wood Storm Windows
Other:
Window size, assembly and installation requirements are to be as specified in the attached drawing No. 1932. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level "D" product. All glass meets the requirements of the current ASTM E1300 standard
Notes:


Date Submitted: July 22, 2020

Date Validated: July 22, 2020

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Window size, assembly and installation requirements are to be as specified in the attached drawing No. 1932. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level "D" product. All glass meets the requirements of the current ASTM E1300 standard

Official Site Status: Approved

Subcategory: Casement
Contact Information
Representative:
N/A
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 07/12/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes