FL23953.16-R0
Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
New
Folio:
Model:
Tite-Loc Plus
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
16" Wide x 0.032" Aluminum Panels over min. 19/32" Plywood Deck
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Locke Bowden - PE-49704
Validator:
Zachary R. Priest, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 16, 2017
Validation Date:
October 29, 2017
Design Pressures:
-74.1psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 00 - Roof Panels
CSI Code: 05 33 23 - Aluminum Roof Decking
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 23 - Wood Roof Panels
Other:
Uplift load of 61.1 psf @ clip spacing of 24" o.c. and 74.1 psf @ clip spacing of 12" o.c. Install per manufacturer's details. Not for use in HVHZ.
Notes:
Date Submitted: October 16, 2017
Date Validated: October 29, 2017
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Uplift load of 61.1 psf @ clip spacing of 24" o.c. and 74.1 psf @ clip spacing of 12" o.c. Install per manufacturer's details. Not for use in HVHZ.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Nicholas Delfino
Address:
102 Northpoint Parkway Building 106,
Acworth, Georgia 30102 USA
Acworth, Georgia 30102 USA
Phone:
Listing Changes
Last Synced: 06/08/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL23953 R0 II FL 23953 PETERSEN ALUMINUM DETAIL BINDER SS

PR TECH DOCS FL23953 R0 AE FL 23953 PETERSEN ALUM REPORT COMPLETE-SS