engineering plans logo black

FL2681.1-R7

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

Bertha Colonial Shutter with clips or storm bars- (Non-HVHZ) Drawing# 23-131

Database:
Florida Product Approval
Source Link:
Description:

Extruded aluminum blades assembled together and retained by jambs/headers to provide hurricane protection

Listing Details
Category:
Impact Protection Devices
Subcategory:
Colonial
Evaluator:
Walter A. Tillit Jr. - PE-44167
Validator:
John Henry Kampmann Jr.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
October 14, 2023
Validation Date:
October 17, 2023
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Possible CSI Codes:
CSI Code: 07 46 16 - Aluminum Siding
CSI Code: 08 12 16 - Aluminum Frames
CSI Code: 05 14 00 - Structural Aluminum Framing
CSI Code: 08 11 69.23 - Aluminum Storm Doors and Frames
CSI Code: 05 14 13 - Architecturally-Exposed Structural Aluminum Framing
Other:
Large missile.Max.width is 72" and max.height is 54" for double panels(square)with clips and +65,-65 psf A.S.D.design load,and max.width is 144" and max. height is 54" for quadruple panels(square)with clips.See sheets 13 and 14 for additional schedules.Max width is 36.5 with Max. height of 67 for +60,-81 psf double (square) panels with storm bars or max. width is 61 with 73 max. height for +51,-70 psf quadruple (square)panels with storm bars.
Notes:


Date Submitted: October 14, 2023

Date Validated: October 17, 2023

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Large missile.Max.width is 72" and max.height is 54" for double panels(square)with clips and +65,-65 psf A.S.D.design load,and max.width is 144" and max. height is 54" for quadruple panels(square)with clips.See sheets 13 and 14 for additional schedules.Max width is 36.5 with Max. height of 67 for +60,-81 psf double (square) panels with storm bars or max. width is 61 with 73 max. height for +51,-70 psf quadruple (square)panels with storm bars.

Official Site Status: Approved

Subcategory: Colonial
Contact Information
Representative:
Bill Feeley
Address:
4268 Westroads Drive,
West Palm Beach, Florida 33407 USA

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/01/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL2681 R7 II DRWING 23-131 COLONIAL
PR INSTL DOCS FL2681 R7 II DRWING 23-131 COLONIAL
PR TECH DOCS FL2681 R7 AE PRODUCT EVALUATION REPORT DRAWING 23-131 COLONIAL
PR TECH DOCS FL2681 R7 AE PRODUCT EVALUATION REPORT DRAWING 23-131 COLONIAL

Your Ad on 100K+ Listings Contact Us
QR Code To This Listing
FL2681.1-R7 Listing QR Code
Shopping Cart