FL2681.1-R7
Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:
Bertha Colonial Shutter with clips or storm bars- (Non-HVHZ) Drawing# 23-131
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Extruded aluminum blades assembled together and retained by jambs/headers to provide hurricane protection
Listing Details
Category:
Impact Protection Devices
Subcategory:
Colonial
Evaluator:
Walter A. Tillit Jr. - PE-44167
Validator:
John Henry Kampmann Jr.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 14, 2023
Validation Date:
October 17, 2023
Possible CSI Codes:
CSI Code: 07 46 16 - Aluminum Siding
CSI Code: 08 12 16 - Aluminum Frames
CSI Code: 05 14 00 - Structural Aluminum Framing
CSI Code: 08 11 69.23 - Aluminum Storm Doors and Frames
CSI Code: 05 14 13 - Architecturally-Exposed Structural Aluminum Framing
Other:
Large missile.Max.width is 72" and max.height is 54" for double panels(square)with clips and +65,-65 psf A.S.D.design load,and max.width is 144" and max. height is 54" for quadruple panels(square)with clips.See sheets 13 and 14 for additional schedules.Max width is 36.5 with Max. height of 67 for +60,-81 psf double (square) panels with storm bars or max. width is 61 with 73 max. height for +51,-70 psf quadruple (square)panels with storm bars.
Notes:
Date Submitted: October 14, 2023
Date Validated: October 17, 2023
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Large missile.Max.width is 72" and max.height is 54" for double panels(square)with clips and +65,-65 psf A.S.D.design load,and max.width is 144" and max. height is 54" for quadruple panels(square)with clips.See sheets 13 and 14 for additional schedules.Max width is 36.5 with Max. height of 67 for +60,-81 psf double (square) panels with storm bars or max. width is 61 with 73 max. height for +51,-70 psf quadruple (square)panels with storm bars.
Official Site Status: Approved
Subcategory: Colonial
Contact Information
Representative:
Bill Feeley
Address:
4268 Westroads Drive,
West Palm Beach, Florida 33407 USA
West Palm Beach, Florida 33407 USA
Phone:
Website:
Listing Changes
Last Synced: 11/08/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL2681 R7 II DRWING 23-131 COLONIAL

PR TECH DOCS FL2681 R7 AE PRODUCT EVALUATION REPORT DRAWING 23-131 COLONIAL
QR Code To This Listing