engineering plans logo black

FL27676.8-R6

Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Revision
Folio:
Model:

M700 Fixed-Awning Impact Window

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

M700 Modern-Vu Fixed-Awning Impact Window

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Awning
Evaluator:
  -  
Validator:
National Accreditation & Management Institute
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
National Accreditation & Management Institute
Specifications
Submission Date:
January 17, 2023
Validation Date:
January 18, 2023
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-70psf / +70psf
Possible CSI Codes:
CSI Code: 10 73 13.36 - Point Supported Glass Awnings
CSI Code: 08 60 00 - Roof Windows and Skylights
CSI Code: 08 01 60 - Operation and Maintenance of Skylights and Roof Windows
CSI Code: 08 55 13 - Tornado-Resistant Windows
CSI Code: 12 24 00 - Window Shades
Other:
AW-PG70-AP Max. Frame Size 60" x 96". Max. Fixed Light DLO 56 1/4"w x 46 13/16"h and Max Project Out Awning DLO 52 5/8"w x 40 5/8"h. 1" Insulating Glass consisting of 1/4" annealed glass Ext. x Super Spacer x 2 lights of 1/8" annealed glass with .090 Kurary PVB Interlayer laminated unit. Wind Zone 3 - Missile Level D. 12psf Water. Nailing Fin, Trim & Clip, and Receptor anchorage - See Installation Instructions Mark B.
Notes:


Date Submitted: January 17, 2023

Date Validated: January 18, 2023

Entity: National Accreditation & Management Institute

Compliance Method: Certification Mark or Listing

Other: AW-PG70-AP Max. Frame Size 60" x 96". Max. Fixed Light DLO 56 1/4"w x 46 13/16"h and Max Project Out Awning DLO 52 5/8"w x 40 5/8"h. 1" Insulating Glass consisting of 1/4" annealed glass Ext. x Super Spacer x 2 lights of 1/8" annealed glass with .090 Kurary PVB Interlayer laminated unit. Wind Zone 3 - Missile Level D. 12psf Water. Nailing Fin, Trim & Clip, and Receptor anchorage - See Installation Instructions Mark B.

Official Site Status: Approved

Subcategory: Awning
Contact Information
Representative:
Fred Grunewald
Address:
PO Box 128 504 Highway 63 South,
Freeburg, Missouri 65035 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/01/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL27676 R6 C CAC NI015457.05
PR CERTIFICATE FL27676 R6 C CAC NI015457.05
PR INSTL DOCS FL27676 R6 II M700 AWN-FIX AND FIX-AWN PE SEALED
PR INSTL DOCS FL27676 R6 II M700 AWN-FIX AND FIX-AWN PE SEALED
PR TECH DOCS FL27676 R6 AE EQUILVENCY LETTER L5048.01-801-44 12-21-22
PR TECH DOCS FL27676 R6 AE EQUILVENCY LETTER L5048.01-801-44 12-21-22
PR TECH DOCS FL27676 R6 AE P2356.01-122-34-R0 (1)
PR TECH DOCS FL27676 R6 AE P2356.01-122-34-R0 (1)

Your Ad on 100K+ Listings Contact Us
QR Code To This Listing
FL27676.8-R6 Listing QR Code
Shopping Cart