engineering plans logo black

FL28127.2-R4

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Affirmation
Folio:
Model:

Premium Coastal DH Operator (48"x84") Mulled to DH Picture (56"x84") Combination

Database:
Florida Product Approval
Source Link:
Description:

1104 Double-Hung (48"x84") Mulled to 1109 DH Picture (56"x84") Insulated Glass. Maximum Tributary Width = 52" based on mull testing & CCL 449-H-074.15 and .17.

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Fixed
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
December 13, 2023
Validation Date:
December 13, 2023
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-70psf / +55psf
Possible CSI Codes:
CSI Code: 04 23 19 - Glass Unit Masonry Skylights
CSI Code: 08 54 69 - Fiberglass Storm Windows
CSI Code: 08 81 23 - Exterior Glass Glazing
CSI Code: 08 54 13 - Fiberglass Windows
CSI Code: 12 17 13 - Etched Glass
Other:
Complies with ASTM E1300. DH IG glass comprised of one lite of 5/32" annealed//8.0mm Endur Spacer//Lami lite comprised of two lites of 3/32" annealed with .090" PVB interlayer. Picture insulated glass make-up consists of one lite of 1/4" annealed//8mm Endur spacer//Lami lite comprised of two lites of 3/16" annealed with .090" PVB interlayer.
Notes:


Date Submitted: December 13, 2023

Date Validated: December 13, 2023

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: Complies with ASTM E1300. DH IG glass comprised of one lite of 5/32" annealed//8.0mm Endur Spacer//Lami lite comprised of two lites of 3/32" annealed with .090" PVB interlayer. Picture insulated glass make-up consists of one lite of 1/4" annealed//8mm Endur spacer//Lami lite comprised of two lites of 3/16" annealed with .090" PVB interlayer.

Official Site Status: Approved

Subcategory: Fixed
Contact Information
Representative:
Valerie Bach
Address:
829 N. 8th Street,
Medford, Wisconsin 54451 US
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/22/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL28127 R4 C CAC 448-H-074.19-.21
PR CERTIFICATE FL28127 R4 C CAC 448-H-074.19-.21
PR CERTIFICATE FL28127 R4 C CAC 449-H-074 15-17 MULLION CCL FOR DH 48X84 MULLED TO DH PICTURE 56X84
PR CERTIFICATE FL28127 R4 C CAC 449-H-074 15-17 MULLION CCL FOR DH 48X84 MULLED TO DH PICTURE 56X84
PR INSTL DOCS FL28127 R4 II 1104-1105 DH THROUGH JAMB
PR INSTL DOCS FL28127 R4 II 1104-1105 DH THROUGH JAMB
PR INSTL DOCS FL28127 R4 II 45-18772 DH OPER-PICTURE COMB
PR INSTL DOCS FL28127 R4 II 45-18772 DH OPER-PICTURE COMB

Your Ad on 100K+ Listings Contact Us
QR Code To This Listing
FL28127.2-R4 Listing QR Code
Shopping Cart