FL29283.4-R0

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
New
Folio:
Model:

1606DHPF

Database:
Florida Product Approval
Source Link:
Description:

1606DHPF, 6" Deep, Extruded Aluminum, Drainable Blade, High Performance

Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Wall Louver
Evaluator:
  -  
Validator:
Intertek Testing Services NA, Inc.
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Intertek Testing Services NA, Inc.
Specifications
Submission Date:
May 29, 2019
Validation Date:
August 6, 2019
Expiration Date:
12/31/2021
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-150psf / +150psf
Possible CSI Codes:
CSI Code: 08 91 16 - Operable Wall Louvers
CSI Code: 07 64 00 - Sheet Metal Wall Cladding
CSI Code: 05 14 00 - Structural Aluminum Framing
CSI Code: 08 12 16 - Aluminum Frames
CSI Code: 10 74 00 - Manufactured Exterior Specialties
Other:
Rated for Enhanced Impact Missile Level "E" (80fps) Load and size ratings in accordance with attached table. Designed to withstand 150 psf wind load. Maximum overall panel size of 108" wide x 84" tall or 120" wide x 84". Non-mulled panels may be stacked to unlimited height. Must have a Fully Closed 2020 damper to pass TAS-100(A) & AMCA550. Compliance per AMCA 550 is for residential use only.
Notes:


Date Submitted: May 29, 2019

Date Validated: August 6, 2019

Entity: Intertek Testing Services NA, Inc.

Compliance Method: Certification Mark or Listing

Other: Rated for Enhanced Impact Missile Level "E" (80fps) Load and size ratings in accordance with attached table. Designed to withstand 150 psf wind load. Maximum overall panel size of 108" wide x 84" tall or 120" wide x 84". Non-mulled panels may be stacked to unlimited height. Must have a Fully Closed 2020 damper to pass TAS-100(A) & AMCA550. Compliance per AMCA 550 is for residential use only.

Official Site Status: Approved

Subcategory: Wall Louver
Contact Information
Representative:
Bill Bailey
Address:
1855 S 54th Avenue,
Cicero, Illinois 60804 United States
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 09/08/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL29283 R0 C CAC SDREPORT LISTING 47857 (1)
PR CERTIFICATE FL29283 R0 C CAC SDREPORT LISTING 47857 (1)
PR INSTL DOCS FL29283 R0 II 1606DHPF 54.00 X 120 FLORIDA LOUVERS -SA
PR INSTL DOCS FL29283 R0 II 1606DHPF 54.00 X 120 FLORIDA LOUVERS -SA
QR Code To This Listing
FL29283.4-R0 Listing QR Code
Shopping Cart