FL29598.1-R2
Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:
ULTIMATE CASEMENT IZ3 RIBBON MULL
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Ultimate Casement Picture IZ3 2W Ribbon Mull Assembly 407-H-917
Listing Details
Specifications
Submission Date:
May 1, 2024
Validation Date:
May 29, 2024
Design Pressures:
-65psf / +65psf
Possible CSI Codes:
CSI Code: 08 62 16 - Pyramidal Unit Skylights
CSI Code: 08 63 16 - Pyramidal Metal-Framed Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 62 00 - Unit Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
Other:
Max Span=83-1/8" (2111mm), Max Tributary=54" (1372mm) CCL listing for AWS testing completed on mulled assembly per AAMA 450-10. For use with all products listed on installation instructions 117198. Glass complies with ASTM E1300. Reference CCL 1024.73.74.75 in place of 1024.43.44.47.48
Notes:
Date Submitted: May 1, 2024
Date Validated: May 29, 2024
Entity: Window and Door Manufacturer Association
Compliance Method: Certification Mark or Listing
Other: Max Span=83-1/8" (2111mm), Max Tributary=54" (1372mm) CCL listing for AWS testing completed on mulled assembly per AAMA 450-10. For use with all products listed on installation instructions 117198. Glass complies with ASTM E1300. Reference CCL 1024.73.74.75 in place of 1024.43.44.47.48
Official Site Status: Approved
Subcategory: Mullions
Contact Information
Representative:
Cheryl Hill
Address:
Hwy 11 West,
Warroad, Minnesota 56763 USA
Warroad, Minnesota 56763 USA
Phone:
Website:
Listing Changes
Last Synced: 03/28/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL29598 R2 C CAC 917.59
PR CERTIFICATE FL29598 R2 C CAC CCL 917.59
PR INSTL DOCS FL29598 R2 II 117198
QR Code To This Listing