FL29969.1-R0
Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
New
Folio:
Model:
Series Dekton Ultra Compact Composite Panel Facade System
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Large missile impact resistant composite facade cladding system.
Listing Details
Specifications
Submission Date:
July 18, 2019
Validation Date:
March 10, 2022
Design Pressures:
-125psf / +125psf
Possible CSI Codes:
CSI Code: 07 05 43 - Cladding Support Systems
CSI Code: 08 44 12 - Glazed Composite Curtain Wall
CSI Code: 10 26 23.16 - Fiberglass Reinforced Protective Wall Covering
CSI Code: 07 64 00 - Sheet Metal Wall Cladding
CSI Code: 08 44 26 - Structural Glass Curtain Walls
Other:
See NOA # 21-1007.03 and Limitations of Use for installation instructions.
Notes:
Date Submitted: July 18, 2019
Date Validated: March 10, 2022
Entity: Miami-Dade BCCO - CER
Compliance Method: Certification Mark or Listing
Other: See NOA # 21-1007.03 and Limitations of Use for installation instructions.
Official Site Status: Approved
Subcategory: Siding
Contact Information
Representative:
Brendan Mercier
Address:
355 Alhambra Circle Ste 1000,
Coral Gables, Florida 33134 United States
Coral Gables, Florida 33134 United States
Phone:
Listing Changes
Last Synced: 03/26/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR CERTIFICATE FL29969 R0 C CAC DEKTON PANEL FACADE SYSTEM(LMI) 21-1007.03

PR INSTL DOCS FL29969 R0 II DEKTON PANEL FACADE SYSTEM(LMI) 21-1007.03

PR INSTL DOCS FL29969 R0 II LIMITATIONS OF USE
QR Code To This Listing