Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Aluminum Fixed windows (small & Large Missile Impact)
Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Fixed
Evaluator:
Warren W. Schaefer - PE-44135
Validator:
T.E. Lunn, PE, LLC
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
July 31, 2023
Validation Date:
July 31, 2023
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Possible CSI Codes:
CSI Code: 08 51 13 - Aluminum Windows
CSI Code: 08 51 69 - Metal Storm Windows
CSI Code: 08 01 60 - Operation and Maintenance of Skylights and Roof Windows
CSI Code: 08 60 00 - Roof Windows and Skylights
CSI Code: 08 51 00 - Metal Windows
Other:
Window size, Pressure, assembly and installation requirements are to be as specified in the attached drawings No.1964. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Building and Other Structures. This windows system is rated as a wind zone 4 missile level "D" product. All glass meets the requirements of the current ASTM E1300 standard
Notes:
Date Submitted: July 31, 2023
Date Validated: July 31, 2023
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Window size, Pressure, assembly and installation requirements are to be as specified in the attached drawings No.1964. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Building and Other Structures. This windows system is rated as a wind zone 4 missile level "D" product. All glass meets the requirements of the current ASTM E1300 standard
Official Site Status: Approved
Subcategory: Fixed
Contact Information
Representative:
Autumn Buckalew
Address:
PO Box 431 2403 S. Main Street, Fort Scott, Kansas 66701 USA