Max 18" wide, nom 0.032" thick (min.) aluminum snap-lock standing seam panel over min 15/32" thick plywood deck
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Bala Sockalingam - PE-62240
Validator:
Yoosef Lavi, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 4, 2020
Validation Date:
October 8, 2020
Design Pressures:
-93.5psf / +0psf
Possible CSI Codes:
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 61 19 - Flat Seam Sheet Metal Roofing
CSI Code: 07 61 00 - Sheet Metal Roofing
Other:
Uplift load of 93.5 psf at clip spacing of 24" o.c.
Notes:
Date Submitted: October 4, 2020
Date Validated: October 8, 2020
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Uplift load of 93.5 psf at clip spacing of 24" o.c.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Bernie Reed
Address:
19 E. Lincoln Drive NE,
Brookhaven, Mississippi 39601 USA
Brookhaven, Mississippi 39601 USA
Phone:
Listing Changes
Last Synced: 06/15/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL31370 R1 II EVALUATIONREPORTC2405 2

PR TECH DOCS FL31370 R1 AE EVALUATIONREPORTC2405 2
QR Code To This Listing