FL32334.1-R1

Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Affirmation
Folio:
Model:

Concealed Balance Double & Single Hung Wood Windows

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

Concealed balance double & single hung windows (Small & Large Missile Impact)

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Double Hung
Evaluator:
Warren W. Schaefer, P.E. - PE-44135
Validator:
T.E. Lunn, PE, LLC
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
August 17, 2020
Validation Date:
August 17, 2020
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Possible CSI Codes:
CSI Code: 08 55 13 - Tornado-Resistant Windows
CSI Code: 12 24 00 - Window Shades
CSI Code: 08 54 00 - Composite Windows
CSI Code: 08 51 69 - Metal Storm Windows
CSI Code: 08 55 00 - Pressure-Resistant Windows
Other:
Window size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1508. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level "D" product. All glass meets the requirements of the current ASTM E1300 standard.
Notes:


Date Submitted: August 17, 2020

Date Validated: August 17, 2020

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Window size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1508. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level "D" product. All glass meets the requirements of the current ASTM E1300 standard.

Official Site Status: Approved

Subcategory: Double Hung
Contact Information
Representative:
Carolina DiMartino
Address:
15951 SW 41 Street Suite 150,
Weston, Florida 33331 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 07/13/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL32334 R1 II DRAWING 1508
PR INSTL DOCS FL32334 R1 II DRAWING 1508
PR TECH DOCS FL32334 R1 AE EVALUATION REPORT WWS-373
PR TECH DOCS FL32334 R1 AE EVALUATION REPORT WWS-373
QR Code To This Listing
FL32334.1-R1 Listing QR Code
Shopping Cart