FL32994.10-R5
Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:
32994.10 PAC T-250 (S1)
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
16" Wide x .032" (min) Aluminum Panel w/Continuous Clips
Listing Details
Specifications
Submission Date:
September 20, 2023
Validation Date:
October 4, 2023
Design Pressures:
-140.4psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 63 - Fabricated Roof Panel Assemblies
CSI Code: 07 41 33 - Plastic Roof Panels
Other:
Uplift load for 16" wide panel is -78.00 PSF w/screw spacing of 60" o.c. and -140.40 PSF w/screw spacing of 24" o.c. Install per manufacturer's details. Not for use in HVHZ.
Notes:
Date Submitted: September 20, 2023
Date Validated: October 4, 2023
Entity:
Compliance Method: Test Report
Other: Uplift load for 16" wide panel is -78.00 PSF w/screw spacing of 60" o.c. and -140.40 PSF w/screw spacing of 24" o.c. Install per manufacturer's details. Not for use in HVHZ.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Nicholas Delfino
Address:
102 Northpoint Parkway Building 106,
Acworth, Georgia 30102 USA
Acworth, Georgia 30102 USA
Phone:
Listing Changes
Last Synced: 10/12/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
None found
QR Code To This Listing