FL33230.1-R5

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

7.2 Panel (S1) 2' - 5' Spans

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

36" Wide x 24 Ga. (min.) Steel

Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Siding
Evaluator:
  -  
Validator:
Donald Flood, FL PE
Official Site Status:
Approved
Compliance Method:
Test Report
Approval Method:
Method 1 Option B
Entity:
 
Specifications
Submission Date:
April 15, 2024
Validation Date:
April 30, 2024
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-159.7psf / +0psf
Possible CSI Codes:
CSI Code: 07 46 19 - Steel Siding
CSI Code: 07 46 00 - Siding
CSI Code: 07 46 63 - Fabricated Panel Assemblies with Siding
CSI Code: 07 46 43 - Composition Siding
CSI Code: 08 44 18 - Glazed Steel Curtain Walls
Other:
Allowable Wind Uplift Pressure, psf. Panel Span, ft: -159.70 @ 2, -132.70 @ 3', -105.80 @ 4', -78.85 @ 5. Not for use in HVHZ. Safety Factor of 2.0 is included.
Notes:


Date Submitted: April 15, 2024

Date Validated: April 30, 2024

Entity:  

Compliance Method: Test Report

Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -159.70 @ 2, -132.70 @ 3', -105.80 @ 4', -78.85 @ 5. Not for use in HVHZ. Safety Factor of 2.0 is included.

Official Site Status: Approved

Subcategory: Siding
Contact Information
Representative:
Nicholas Delfino
Address:
102 Northpoint Parkway Building 106,
Acworth, Georgia 30102 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 01/02/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL33230 R5 II INSTALLATION DETAILS ALL
PR INSTL DOCS FL33230 R5 II INSTALLATION DETAILS ALL
PR INSTL DOCS FL33230 R5 II NEGATIVE LOAD TABLE 2 TO 5 FT SPANS
PR INSTL DOCS FL33230 R5 II NEGATIVE LOAD TABLE 2 TO 5 FT SPANS
PR TECH DOCS FL33230 R5 TR 2651A0001 REPORT ASTM E1886 PETERSEN 24GA 7.2 RIB PANEL
PR TECH DOCS FL33230 R5 TR 2651A0001 REPORT ASTM E1886 PETERSEN 24GA 7.2 RIB PANEL
PR TECH DOCS FL33230 R5 TR T277-08 E1592 24 GA
PR TECH DOCS FL33230 R5 TR T277-08 E1592 24 GA
QR Code To This Listing
FL33230.1-R5 Listing QR Code
Shopping Cart