FL33286.6-R3

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Affirmation
Folio:
Model:

EV [04 or 08] E-Class

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

Aluminum Frame Self-Flashed Manual-Venting Skylight, (non-impact), size 3054 and smaller (426-H-729.08/.09)

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
July 13, 2023
Validation Date:
July 13, 2023
HVHZ Approved:
No
Impact Resistant:
No [FL]
Design Pressures:
-40psf / +40psf
Possible CSI Codes:
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 62 00 - Unit Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 63 53 - Motorized Metal-Framed Skylights
CSI Code: 08 63 16 - Pyramidal Metal-Framed Skylights
Other:
SKG-PG40, max size 889mm x 1499mm (36" x 60"). PG 40 means minimum capacity is 40 psf. Glass meets ASTM E1300: 3mm clear tempered/10.5mm st. stl. spacer/5.3mm laminate using two 2.3mm panes and 0.030" PVB interlayer (with white coating for variant 08). Anchoring to roof deck: mounting bracket spacing approx. 6" from corners (4" on 14" side) and in the middle of side when 3 are used, fill all pre-punched holes in mounting brackets with supplied screws.
Notes:


Date Submitted: July 13, 2023

Date Validated: July 13, 2023

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: SKG-PG40, max size 889mm x 1499mm (36" x 60"). PG 40 means minimum capacity is 40 psf. Glass meets ASTM E1300: 3mm clear tempered/10.5mm st. stl. spacer/5.3mm laminate using two 2.3mm panes and 0.030" PVB interlayer (with white coating for variant 08). Anchoring to roof deck: mounting bracket spacing approx. 6" from corners (4" on 14" side) and in the middle of side when 3 are used, fill all pre-punched holes in mounting brackets with supplied screws.

Official Site Status: Approved

Subcategory: Skylight
Contact Information
Representative:
Mike Rhoden
Address:
P.O. Box 5001,
Greenwood, South Caroli 29648 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 08/25/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL33286 R3 C CAC VELUX CCL EV 3054 04-08
PR CERTIFICATE FL33286 R3 C CAC VELUX CCL EV 3054 04-08
PR INSTL DOCS FL33286 R3 II ECLASS-ASPHALT-SHINGLE-INSTALLATION 0519
PR INSTL DOCS FL33286 R3 II ECLASS-ASPHALT-SHINGLE-INSTALLATION 0519
PR INSTL DOCS FL33286 R3 II ECLASS-METAL-ROOF-INSTALLATION INSTRUCTIONS 0518
PR INSTL DOCS FL33286 R3 II ECLASS-METAL-ROOF-INSTALLATION INSTRUCTIONS 0518
QR Code To This Listing
FL33286.6-R3 Listing QR Code
Shopping Cart