FL33364.1-R3

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

Flush Glazed Skylight

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

Skylight system made of laminated heat strengthened glass retained by aluminum profile, wet glazed.

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
Walter A. Tillit Jr., P.E. - PE-44167
Validator:
John W. Knezevich, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
December 13, 2025
Validation Date:
December 13, 2025
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-75psf / +75psf
Possible CSI Codes:
CSI Code: 08 01 60 - Operation and Maintenance of Skylights and Roof Windows
CSI Code: 04 23 19 - Glass Unit Masonry Skylights
CSI Code: 08 60 00 - Roof Windows and Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 01 64 - Operation and Maintenance of Plastic-Framed Skylights
Other:
Large & Small Missile Impact Resistant, see General Note No. 2, sheet 1 of installation drawing No. 23-096. A.S.D. Pressure rating given for unit size 49.75" x 97.75". See Item 7 of Product Evaluation Report for Limitations and Conditions of Use.
Notes:


Date Submitted: December 13, 2025

Date Validated: December 13, 2025

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Large & Small Missile Impact Resistant, see General Note No. 2, sheet 1 of installation drawing No. 23-096. A.S.D. Pressure rating given for unit size 49.75" x 97.75". See Item 7 of Product Evaluation Report for Limitations and Conditions of Use.

Official Site Status: Approved

Subcategory: Skylight
Contact Information
Representative:
Myron Goodrich
Address:
2710 NW 30 AV,
Lauderdale Lakes, Florida 33311
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information
Listing Changes
Last Synced: 06/26/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL33364 R3 II PED SKYLIGHT CONCEPTS DWG 23-096
PR INSTL DOCS FL33364 R3 II PED SKYLIGHT CONCEPTS DWG 23-096
PR TECH DOCS FL33364 R3 AE PER SKYLIGHT CONCEPTS DWG 23-096
PR TECH DOCS FL33364 R3 AE PER SKYLIGHT CONCEPTS DWG 23-096
QR Code To This Listing
FL33364.1-R3 Listing QR Code
Shopping Cart