FL3546.1-R9
Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:
D.C.S.M. VS-150
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Snap-Lock Standing Seam Panel
Listing Details
Specifications
Submission Date:
January 17, 2020
Validation Date:
February 10, 2020
Design Pressures:
-86psf / +0psf
Possible CSI Codes:
CSI Code: 07 61 13 - Standing Seam Sheet Metal Roofing
CSI Code: 07 61 19 - Flat Seam Sheet Metal Roofing
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 61 16 - Batten Seam Sheet Metal Roofing
CSI Code: 07 03 61.13 - Conservation Treatment for Period Standing Seam Sheet Metal Roofing
Other:
Notes:
Date Submitted: January 17, 2020
Date Validated: February 10, 2020
Entity: Miami-Dade BCCO - CER
Compliance Method: Certification Mark or Listing
Other:
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
N/A
Listing Changes
Last Synced: 06/30/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR CERTIFICATE FL3546 R9 C CAC DCSM VS150 MIAMI DADE NOA 19-0109.05

PR INSTL DOCS FL3546 R9 II DCSM VS-150 COMPLETE INSTALLATION DETAILS

PR INSTL DOCS FL3546 R9 II DCSM VS150 MIAMI DADE NOA 19-0109.05
QR Code To This Listing