FL40241.2-R1

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Affirmation
Folio:
Model:

VELUX VMS Fixed Longlight (Impact)

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

HFC fixed module (Impact) size 1000mm x 3000mm or smaller (426-H-728.00/.01/.09)

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
July 13, 2023
Validation Date:
July 13, 2023
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-50psf / +50psf
Possible CSI Codes:
CSI Code: 08 62 00 - Unit Skylights
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 01 64 - Operation and Maintenance of Plastic-Framed Skylights
CSI Code: 08 63 13 - Domed Metal-Framed Skylights
Other:
SKG-PG60, Wind Zone 3, Missile Level C, Design Press. +60/-100, Cycle Press. +50/-50, max size 1000mm x 3000mm (39.4" x 118.1"). Tested ASTM E1886/ASTM E1996. Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and 2.28mm (0.090") PVB interlayer. Details for anchoring to site-built curb in installation instructions.
Notes:


Date Submitted: July 13, 2023

Date Validated: July 13, 2023

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: SKG-PG60, Wind Zone 3, Missile Level C, Design Press. +60/-100, Cycle Press. +50/-50, max size 1000mm x 3000mm (39.4" x 118.1"). Tested ASTM E1886/ASTM E1996. Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and 2.28mm (0.090") PVB interlayer. Details for anchoring to site-built curb in installation instructions.

Official Site Status: Approved

Subcategory: Skylight
Contact Information
Representative:
Mike Rhoden
Address:
P.O. Box 5001,
Greenwood, South Caroli 29648 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 07/09/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL40241 R1 II VMS LONGLIGHT INSTALL INSTRUCTIONS
PR INSTL DOCS FL40241 R1 II VMS LONGLIGHT INSTALL INSTRUCTIONS
PR INSTL DOCS FL40241 R1 II VMS LONGLIGHT SUBCONSTRUCTION INSTALL INSTRUCTIONS
PR INSTL DOCS FL40241 R1 II VMS LONGLIGHT SUBCONSTRUCTION INSTALL INSTRUCTIONS
PR CERTIFICATE FL40241 R1 C CAC LONGLIGHT HFC 100300 OR SMALLER
PR CERTIFICATE FL40241 R1 C CAC LONGLIGHT HFC 100300 OR SMALLER
QR Code To This Listing
FL40241.2-R1 Listing QR Code
Shopping Cart