Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Dynamic Polycarbonate Double Dome Fixed Curb Mount Skylight - Impact Resistant, 4' x 8' size and smaller (426-H-731.64/.65/.68).
Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
-
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
March 20, 2023
Validation Date:
March 30, 2023
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-80psf / +80psf
Possible CSI Codes:
CSI Code: 08 63 13 - Domed Metal-Framed Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 62 13 - Domed Unit Skylights
CSI Code: 08 63 00 - Metal-Framed Skylights
Other:
Wind Zone 4, Missile Level D, Cycle Press. +80/-80, Design Press. +80/-80 psf. SKP-PG80, max size 1327mm x 2546mm (52.25" x 100.25"). PG80 means minimum capacity is 80 psf. Tested ASTM E1886/E1996. Class A Burn-rated dome. Exterior dome is smooth polycarb over interior smooth polycarb. Anchoring to curb: Fill all pre-drilled holes in skylight frame with supplied screws.
Notes:
Date Submitted: March 20, 2023
Date Validated: March 30, 2023
Entity: Window and Door Manufacturer Association
Compliance Method: Certification Mark or Listing
Other: Wind Zone 4, Missile Level D, Cycle Press. +80/-80, Design Press. +80/-80 psf. SKP-PG80, max size 1327mm x 2546mm (52.25" x 100.25"). PG80 means minimum capacity is 80 psf. Tested ASTM E1886/E1996. Class A Burn-rated dome. Exterior dome is smooth polycarb over interior smooth polycarb. Anchoring to curb: Fill all pre-drilled holes in skylight frame with supplied screws.