Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Min. 26 ga., 39.4" wide through fastened roof panel over min. 19/32" thick plywood deck
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Bala Sockalingam - PE-62240
Validator:
Yoosef Lavi, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
May 30, 2023
Validation Date:
June 7, 2023
HVHZ Approved:
No
Impact Resistant:
[ None ]
Design Pressures:
-149.6psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 05 31 23 - Steel Roof Decking
Other:
Uplift load of 50.4 psf at fastener spacing of 36" o.c., 106.8 psf at fastener spacing of 24" o.c. and 149.6 psf at fastener spacing of 12" o.c.
Notes:
Date Submitted: May 30, 2023
Date Validated: June 7, 2023
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Uplift load of 50.4 psf at fastener spacing of 36" o.c., 106.8 psf at fastener spacing of 24" o.c. and 149.6 psf at fastener spacing of 12" o.c.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Nathan Libbey
Address:
1652 S. Lee Hwy, Cleveland, Tennessee 37311 United States