FL42128.3-R0
Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
New
Folio:
Model:
MaxSeam
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Max 14" wide, min 26 ga. snap-lock standing seam metal panel over min 15/32" thick plywood
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Bala Sockalingam - PE-62240
Validator:
Yoosef Lavi, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
June 17, 2023
Validation Date:
June 19, 2023
Design Pressures:
-102.2psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 71 00 - Roof Specialties
CSI Code: 07 61 00 - Sheet Metal Roofing
Other:
Uplift load of 102.2 psf at clip spacing of 6" o.c.
Notes:
Date Submitted: June 17, 2023
Date Validated: June 19, 2023
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Uplift load of 102.2 psf at clip spacing of 6" o.c.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
N/A
Website:
Listing Changes
Last Synced: 03/19/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL42128 R0 II EVALUATIONREPORTC2655 3

PR TECH DOCS FL42128 R0 AE EVALUATIONREPORTC2655 3
QR Code To This Listing