FL42209.1-R0

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
New
Folio:
Model:

place holder

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

place holder

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Fixed
Evaluator:
Frank Bennardo, PE - PE-46549
Validator:
John Henry Kampmann Jr.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
July 20, 2023
Validation Date:
September 4, 2023
HVHZ Approved:
Yes
Impact Resistant:
No [FL]
Design Pressures:
-75psf / +75psf
Possible CSI Codes:
CSI Code: 08 01 60 - Operation and Maintenance of Skylights and Roof Windows
CSI Code: 08 01 64 - Operation and Maintenance of Plastic-Framed Skylights
CSI Code: 08 60 00 - Roof Windows and Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 63 53 - Motorized Metal-Framed Skylights
Other:
PG 75 max. size 48x 82 picture window. 3/4" tempered glass, 1/2" glass bite, interior glazed into silicone (XtraBond 450 Neutral Cure Silicone Sealant) with snap in vinyl glazing bead. This product is designed for use in the HVHZ. In wind borne debris regions, this product must be used in a room that is physically isolated from the main structure and is designed as a partially enclosed structure, unless impact protection is provided.
Notes:


Date Submitted: July 20, 2023

Date Validated: September 4, 2023

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: PG 75 max. size 48x 82 picture window. 3/4" tempered glass, 1/2" glass bite, interior glazed into silicone (XtraBond 450 Neutral Cure Silicone Sealant) with snap in vinyl glazing bead. This product is designed for use in the HVHZ. In wind borne debris regions, this product must be used in a room that is physically isolated from the main structure and is designed as a partially enclosed structure, unless impact protection is provided.

Official Site Status: Approved

Subcategory: Fixed
Contact Information
Representative:
N/A
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information
Listing Changes
Last Synced: 09/26/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL42209 R0 II DS-23-61359A 230 FIXED 48X82 (2023 FSA)
PR INSTL DOCS FL42209 R0 II DS-23-61359A 230 FIXED 48X82 (2023 FSA)
PR INSTL DOCS FL42209 R0 II PLACE HOLDER
PR INSTL DOCS FL42209 R0 II PLACE HOLDER
PR TECH DOCS FL42209 R0 AE S-23-61359 - FL42209.1 - EVAL
PR TECH DOCS FL42209 R0 AE S-23-61359 - FL42209.1 - EVAL
QR Code To This Listing
FL42209.1-R0 Listing QR Code
Shopping Cart