Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
MgO skin and Type I Expanded Polystyrene core Structurally Insulated Panels use in applications including areas prone to wind-born debris (high-velocity hurricane zones).
Listing Details
Category:
Components, Fasteners, Materials
Subcategory:
Structural Wall
Evaluator:
-
Validator:
QAI Laboratories
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
QAI Laboratories
Specifications
Submission Date:
December 14, 2023
Validation Date:
January 3, 2024
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-110psf / +110psf
Possible CSI Codes:
CSI Code: 07 42 13.19 - Insulated Metal Wall Panels
CSI Code: 07 41 16 - Insulated Metal Roof Panels
CSI Code: 07 42 13.23 - Metal Composite Material Wall Panels
CSI Code: 07 42 13 - Metal Wall Panels
CSI Code: 07 44 33 - Metal Faced Panels
Other:
Connection details, and load capacities to resist in service loads are to be determined in accordance with Chapter 16 of the 2023 Florida Building Code and Engineering Design for site for use up to maximum design pressures noted above.
Notes:
Date Submitted: December 14, 2023
Date Validated: January 3, 2024
Entity: QAI Laboratories
Compliance Method: Certification Mark or Listing
Other: Connection details, and load capacities to resist in service loads are to be determined in accordance with Chapter 16 of the 2023 Florida Building Code and Engineering Design for site for use up to maximum design pressures noted above.