FL4622.1-R8

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Affirmation
Folio:
Model:

Steelcraft Borrowed Lite System

Database:
Florida Product Approval
Source Link:
Description:

Lite System for use in conjunction with Storefront Entrance System

Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Storefronts
Evaluator:
Hermes F. Norero, P.E. - PE-73778
Validator:
Locke Bowden P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
October 4, 2017
Validation Date:
October 4, 2017
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-60psf / +60psf
Possible CSI Codes:
CSI Code: 08 01 40 - Operation and Maintenance of Entrances, Storefronts, and Curtain Walls
CSI Code: 08 40 00 - Entrances, Storefronts, and Curtain Walls
CSI Code: 08 41 23 - Steel-Framed Entrances and Storefronts
CSI Code: 08 41 26 - All-Glass Entrances and Storefronts
CSI Code: 08 41 16 - Bronze-Framed Entrances and Storefronts
Other:
Construction includes 16 gage min. hollow metal frame system 5 3/4 in. min. jamb depth. Utilizes 9/16 in. min. thick impact resistant laminated glazing. May also use 3/8 in. min. thick non-impact rated tempered glass. Tempered Glass is to be used with approved shutter system inside of wind-borne region.
Notes:


Date Submitted: October 4, 2017

Date Validated: October 4, 2017

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Construction includes 16 gage min. hollow metal frame system 5 3/4 in. min. jamb depth. Utilizes 9/16 in. min. thick impact resistant laminated glazing. May also use 3/8 in. min. thick non-impact rated tempered glass. Tempered Glass is to be used with approved shutter system inside of wind-borne region.

Official Site Status: Approved

Subcategory: Storefronts
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 10/03/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL4622 R8 II 1107W SS 2016-08-31
PR INSTL DOCS FL4622 R8 II 1107W SS 2016-08-31
PR TECH DOCS FL4622 R8 AE PER4463 SS 2016-08-31
PR TECH DOCS FL4622 R8 AE PER4463 SS 2016-08-31
QR Code To This Listing
FL4622.1-R8 Listing QR Code
Shopping Cart