Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
February 28, 2024
Validation Date:
March 5, 2024
HVHZ Approved:
No
Impact Resistant:
No [FL]
Design Pressures:
-57.8psf / +47.5psf
Possible CSI Codes:
CSI Code: 08 13 73 - Sliding Metal Doors
CSI Code: 08 15 73 - Sliding Plastic Doors
CSI Code: 08 16 73 - Sliding Composite Doors
CSI Code: 08 14 73 - Sliding Wood Doors
CSI Code: 08 11 73 - Sliding Metal Fire Doors
Other:
Non HVHZ only. Door Size (DS): 12'W x 56'H max. Max Pressures (MP)cladding: +/- 55.3 psf; Door Framing (DF)+47.5/-57.8 psf. DS: 16'W x 40'H max, MP cladding: +/-55.3 psf. DF: +43/-47 psf. DS: 21'W x 45'H max; MP cladding +/- 55.3 psf. DF: +42.4/-47.5 psf. A structural horizontal brace is required installation @ 20' above floor level in the occurrence of a hurricane warning. The use of this panel for shear diaphragm is outside the scope of this product approval.
Notes:
Date Submitted: February 28, 2024
Date Validated: March 5, 2024
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Non HVHZ only. Door Size (DS): 12'W x 56'H max. Max Pressures (MP)cladding: +/- 55.3 psf; Door Framing (DF)+47.5/-57.8 psf. DS: 16'W x 40'H max, MP cladding: +/-55.3 psf. DF: +43/-47 psf. DS: 21'W x 45'H max; MP cladding +/- 55.3 psf. DF: +42.4/-47.5 psf. A structural horizontal brace is required installation @ 20' above floor level in the occurrence of a hurricane warning. The use of this panel for shear diaphragm is outside the scope of this product approval.