FL47360.2-R0
Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
New
Folio:
Model:
Elite Rib Roof Panel
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
26 ga Elite Rib Roof Panel into Pine Purlins
Listing Details
Specifications
Submission Date:
February 26, 2025
Validation Date:
February 28, 2025
Design Pressures:
-164.7psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 23 - Wood Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 43 - Composite Roof Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
Other:
Per UL580 / UL1897 Tests with pine purlins spaced at 24" on centers, fastener pattern 9/9/9/6 with Safety Factor of 2.0.
Notes:
Date Submitted: February 26, 2025
Date Validated: February 28, 2025
Entity:
Compliance Method: Test Report
Other: Per UL580 / UL1897 Tests with pine purlins spaced at 24" on centers, fastener pattern 9/9/9/6 with Safety Factor of 2.0.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Kyle McLeod
Address:
10121 88th Trace,
Live Oak, Florida 32064 United States
Live Oak, Florida 32064 United States
Phone:
Listing Changes
Last Synced: 04/02/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL47360 R0 II T329-24-ELITE

PR INSTL DOCS FL47360 R0 II T329-24-ELITE

PR TECH DOCS FL47360 R0 TR T329-24-ELITE

PR TECH DOCS FL47360 R0 TR T329-24-ELITE
QR Code To This Listing