engineering plans logo black

FL47414.13-R0

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
New
Folio:
Model:

VELUX SFRD/SFDA 4646 (Self Flash) Polycarb Impact Double Dome Skylight (TAS)

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

SFRD/SFDA Aluminum Self-Flash Fixed Impact Resistant Skylight, size 4646 and smaller (426-H-732.28/.29/.45)

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
March 31, 2025
Validation Date:
April 4, 2025
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-80psf / +70psf
Possible CSI Codes:
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 63 53 - Motorized Metal-Framed Skylights
CSI Code: 08 63 16 - Pyramidal Metal-Framed Skylights
Other:
TAS 201/202/203, Wind Zone 4, Missile Level D, Cycle Pressure +100/-100 psf. SKP-PG105, max size 1490mm x 1490mm (54.625" x 54.625"). PG105 means minimum capacity is 105 psf. Class A Burn-rated dome. Exterior and interior domes are smooth polycarbonate. Anchor flashing to roof deck using supplied #10 hot-dipped zinc coated carbon steel ring shank nails. Fill all pre-drilled holes in Flashing with nails. Use longest 2" length nails in each of the 4 flashing corners.
Notes:


Date Submitted: March 31, 2025

Date Validated: April 4, 2025

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: TAS 201/202/203, Wind Zone 4, Missile Level D, Cycle Pressure +100/-100 psf. SKP-PG105, max size 1490mm x 1490mm (54.625" x 54.625"). PG105 means minimum capacity is 105 psf. Class A Burn-rated dome. Exterior and interior domes are smooth polycarbonate. Anchor flashing to roof deck using supplied #10 hot-dipped zinc coated carbon steel ring shank nails. Fill all pre-drilled holes in Flashing with nails. Use longest 2" length nails in each of the 4 flashing corners.

Official Site Status: Approved

Subcategory: Skylight
Contact Information
Representative:
Mike Rhoden
Address:
P.O. Box 5001,
Greenwood, South Caroli 29648 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/19/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL47414 R0 II VELUX SFRD-SFDA INSTALLATION INSTRUCTIONS
PR INSTL DOCS FL47414 R0 II VELUX SFRD-SFDA INSTALLATION INSTRUCTIONS
PR CERTIFICATE FL47414 R0 C CAC VELUX CCL SFRD-SFDA 4646 SELF-FLASH IMPACT POLYCARB SKYLIGHT- TAS
PR CERTIFICATE FL47414 R0 C CAC VELUX CCL SFRD-SFDA 4646 SELF-FLASH IMPACT POLYCARB SKYLIGHT- TAS

Your Ad on 100K+ Listings Contact Us
QR Code To This Listing
FL47414.13-R0 Listing QR Code
Shopping Cart