FL47414.17-R2
Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:
VELUX SFRD/SFDA 4646 (Self Flash) Polycarb Impact Double Dome Skylight (Impact)
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
SFRD/SFDA Aluminum Self-Flash Fixed Impact Resistant Skylight, size 4646 and smaller (426-H-732.28/.29/.46)
Listing Details
Specifications
Submission Date:
December 11, 2025
Validation Date:
January 14, 2026
Design Pressures:
-100psf / +100psf
Possible CSI Codes:
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 08 63 53 - Motorized Metal-Framed Skylights
CSI Code: 08 63 16 - Pyramidal Metal-Framed Skylights
Other:
Wind Zone 4, Missile Level D, Cycle Pressure +100/-100 psf. SKP-PG105, max size 1490mm x 1490mm (58.66" x 58.66"). PG105 means minimum capacity is 105 psf. Tested ASTM E1886/E1996. Class A Burn-rated dome. Exterior and interior domes are smooth polycarbonate. Anchor flashing to roof deck using supplied #10 hot-dipped zinc coated carbon steel ring shank nails. Fill all pre-drilled holes in Flashing with nails. Use longest 2" length nails in each of the 4 flashing corners.
Notes:
Date Submitted: December 11, 2025
Date Validated: January 14, 2026
Entity: Window and Door Manufacturer Association
Compliance Method: Certification Mark or Listing
Other: Wind Zone 4, Missile Level D, Cycle Pressure +100/-100 psf. SKP-PG105, max size 1490mm x 1490mm (58.66" x 58.66"). PG105 means minimum capacity is 105 psf. Tested ASTM E1886/E1996. Class A Burn-rated dome. Exterior and interior domes are smooth polycarbonate. Anchor flashing to roof deck using supplied #10 hot-dipped zinc coated carbon steel ring shank nails. Fill all pre-drilled holes in Flashing with nails. Use longest 2" length nails in each of the 4 flashing corners.
Official Site Status: Approved
Subcategory: Skylight
Contact Information
Representative:
Mike Rhoden
Address:
P.O. Box 5001,
Greenwood, South Caroli 29648 USA
Greenwood, South Caroli 29648 USA
Phone:
Website:
Listing Changes
Last Synced: 03/22/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL47414 R2 II VELUX SFRD-SFDA INSTALLATION INSTRUCTIONS

PR CERTIFICATE FL47414 R2 C CAC VELUX CCL SFRD-SFDA 4646 SELF-FLASH IMPACT POLYCARB SKYLIGHT- ASTM
QR Code To This Listing