FL47414.5-R2

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

VELUX CMD/CMDA 4672 (Curb Mount) Polycarb Impact Double Dome Skylight (ASTM)

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

CMD/CMDA Aluminum Curb Mount Fixed Impact Resistant Skylight, size 4672 and smaller (426-H-732.61/.62/.64)

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
December 11, 2025
Validation Date:
January 14, 2026
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-65psf / +50psf
Possible CSI Codes:
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 63 53 - Motorized Metal-Framed Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 63 19 - Vaulted Metal-Framed Skylights
Other:
Wind Zone 4, Missile Level D, Cycle Pressure +50/-50 psf. SKP-PG50, max size 1301mm x 1962mm (51.25" x 77.25"). PG50 means minimum capacity is 50 psf. Class A Burn-rated dome. Exterior and interior domes are smooth polycarbonate. Anchoring to site-built curb using supplied #8 1.75" stainless steel panhead screws. Fill all pre-drilled holes with screws. 49.5" x 75.5" R/O for 4672 size.
Notes:


Date Submitted: December 11, 2025

Date Validated: January 14, 2026

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: Wind Zone 4, Missile Level D, Cycle Pressure +50/-50 psf. SKP-PG50, max size 1301mm x 1962mm (51.25" x 77.25"). PG50 means minimum capacity is 50 psf. Class A Burn-rated dome. Exterior and interior domes are smooth polycarbonate. Anchoring to site-built curb using supplied #8 1.75" stainless steel panhead screws. Fill all pre-drilled holes with screws. 49.5" x 75.5" R/O for 4672 size.

Official Site Status: Approved

Subcategory: Skylight
Contact Information
Representative:
Mike Rhoden
Address:
P.O. Box 5001,
Greenwood, South Caroli 29648 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 03/22/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL47414 R2 II VELUX CMD-CMDA INSTALLATION INSTRUCTIONS
PR INSTL DOCS FL47414 R2 II VELUX CMD-CMDA INSTALLATION INSTRUCTIONS
PR CERTIFICATE FL47414 R2 C CAC VELUX CCL CMD-CMDA 4672 CURB-MOUNT IMPACT POLYCARB SKYLIGHT- ASTM
PR CERTIFICATE FL47414 R2 C CAC VELUX CCL CMD-CMDA 4672 CURB-MOUNT IMPACT POLYCARB SKYLIGHT- ASTM
QR Code To This Listing
FL47414.5-R2 Listing QR Code