FL47414.7-R2

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

VELUX CMDG 4646 (Curb Mount) Polycarb Dome over Insulated Glass Skylight - Non-Impact

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

CMDG Aluminum Curb Mount Fixed Skylight, size 4646 and smaller (426-H-732.00/.01)

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
December 11, 2025
Validation Date:
January 14, 2026
HVHZ Approved:
No
Impact Resistant:
No [FL]
Design Pressures:
-60psf / +140psf
Possible CSI Codes:
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 63 13 - Domed Metal-Framed Skylights
CSI Code: 08 63 53 - Motorized Metal-Framed Skylights
CSI Code: 08 62 00 - Unit Skylights
Other:
SKP-PG60, max size 1301mm x 1301mm (51.25" x 51.25"). PG60 means minimum capacity is 60psf. Class A Burn-rated dome. Exterior dome is smooth polycarb over 3mm clear tempered / 8.5mm Tp spacer / 5.4mm laminate using two 2.3mm panes and 0.76" PVB interlayer. Lo-E 366 coating. (Glass meets ASTM E1300). Anchoring to site-built curb using supplied #8 1.75" stainless steel panhead screws. Fill all pre-drilled holes with screws.
Notes:


Date Submitted: December 11, 2025

Date Validated: January 14, 2026

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: SKP-PG60, max size 1301mm x 1301mm (51.25" x 51.25"). PG60 means minimum capacity is 60psf. Class A Burn-rated dome. Exterior dome is smooth polycarb over 3mm clear tempered / 8.5mm Tp spacer / 5.4mm laminate using two 2.3mm panes and 0.76" PVB interlayer. Lo-E 366 coating. (Glass meets ASTM E1300). Anchoring to site-built curb using supplied #8 1.75" stainless steel panhead screws. Fill all pre-drilled holes with screws.

Official Site Status: Approved

Subcategory: Skylight
Contact Information
Representative:
Mike Rhoden
Address:
P.O. Box 5001,
Greenwood, South Caroli 29648 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 03/15/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL47414 R2 C CAC VELUX CCL CMDG 4646 2004C CURB-MOUNT POLYCARB OVER GLASS SKYLIGHT
PR CERTIFICATE FL47414 R2 C CAC VELUX CCL CMDG 4646 2004C CURB-MOUNT POLYCARB OVER GLASS SKYLIGHT
PR INSTL DOCS FL47414 R2 II VELUX CMDG INSTALLATION INSTRUCTIONS
PR INSTL DOCS FL47414 R2 II VELUX CMDG INSTALLATION INSTRUCTIONS
QR Code To This Listing
FL47414.7-R2 Listing QR Code
Shopping Cart