engineering plans logo black

FL47414.8-R1

Report Status
Pending
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

VELUX SFHG 4646 (Self Flash) 2015 Insulted Glass Skylight - Non-Impact

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

SFHG Aluminum Self-Flash Fixed Skylight, size 4646 and smaller (426-H-732.53/.54

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Applied For
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
June 16, 2025
Validation Date:
Unknown
HVHZ Approved:
No
Impact Resistant:
No [FL]
Design Pressures:
-80psf / +80psf
Possible CSI Codes:
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 62 00 - Unit Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 08 63 53 - Motorized Metal-Framed Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
Other:
SKP-PG80, max size 1301mm x 1301mm (51.25" x 51.25"). PG80 means minimum capacity 80psf. Glass meets ASTM E1300: 3mm clear tempered with Lo-E366 (or Lo-E340 for 2015 variant) on surface 2/10.5mm st. stl. spacer/3mm clear tempered (with 2nd Lo-E coating on surface 4 for 2088 variant). Anchor flashing to roof deck using supplied #10 hot-dipped zinc coated carbon steel ring shank nails. Fill all pre-drilled Flashing holes with nails. Use longest 2" length nails in 4 flashing corners.
Notes:


Date Submitted: June 16, 2025

Date Validated: Unknown

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: SKP-PG80, max size 1301mm x 1301mm (51.25" x 51.25"). PG80 means minimum capacity 80psf. Glass meets ASTM E1300: 3mm clear tempered with Lo-E366 (or Lo-E340 for 2015 variant) on surface 2/10.5mm st. stl. spacer/3mm clear tempered (with 2nd Lo-E coating on surface 4 for 2088 variant). Anchor flashing to roof deck using supplied #10 hot-dipped zinc coated carbon steel ring shank nails. Fill all pre-drilled Flashing holes with nails. Use longest 2" length nails in 4 flashing corners.

Official Site Status: Applied For

Subcategory: Skylight
Contact Information
Representative:
Mike Rhoden
Address:
P.O. Box 5001,
Greenwood, South Caroli 29648 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/19/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL47414 R1 C CAC FL47414 VELUX SFHG 4646 OR SMALLER 2015
PR CERTIFICATE FL47414 R1 C CAC FL47414 VELUX SFHG 4646 OR SMALLER 2015
PR INSTL DOCS FL47414 R1 II SFHD-SFHG INSTALLATION INSTRUCTIONS
PR INSTL DOCS FL47414 R1 II SFHD-SFHG INSTALLATION INSTRUCTIONS