FL5388.5-R8
Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:
7 13/16" 1600 System 2 - LMI
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
7 13/16" 1600 System 2 Aluminum Curtain Wall - LMI
Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Curtain Walls
Evaluator:
Warren W. Schaefer - PE-44135
Validator:
T.E. Lunn, PE, LLC
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
August 3, 2018
Validation Date:
August 9, 2018
Possible CSI Codes:
CSI Code: 08 44 26 - Structural Glass Curtain Walls
CSI Code: 11 61 33.19 - Curtain Systems
CSI Code: 08 44 26.16 - Metal Framed Point Supported Glass Curtain Walls
CSI Code: 08 44 13 - Glazed Aluminum Curtain Walls
CSI Code: 08 44 26.13 - Glass Framed Point Supported Glass Curtain Walls
Other:
Curtain wall size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1791. Job required design wind pressure shall be calculated in accordance with the Florida Building code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This curtain wall system is rated as a wind zone 4 large missile level D product. All glass meets the requirements of the current ASTM E1300 standard.
Notes:
Date Submitted: August 3, 2018
Date Validated: August 9, 2018
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Curtain wall size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1791. Job required design wind pressure shall be calculated in accordance with the Florida Building code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This curtain wall system is rated as a wind zone 4 large missile level D product. All glass meets the requirements of the current ASTM E1300 standard.
Official Site Status: Approved
Subcategory: Curtain Walls
Contact Information
Representative:
Khanh Bui
Address:
555 Guthridge Court,
Norcross, Georgia 30092 USA
Norcross, Georgia 30092 USA
Phone:
Website:
Listing Changes
Last Synced: 05/28/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL5388 R8 II ADDENDUM A FOR SYSTEM 2 LMI SMI

PR INSTL DOCS FL5388 R8 II DRAWING 1791

PR TECH DOCS FL5388 R8 AE EVALUATION REPORT WWS-298