FL6095.3-R6
Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Revision
Folio:
Model:
03: Super Pro
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
29 Ga. Super Pro Roof Panel over 15/32" Plywood
Listing Details
Specifications
Submission Date:
September 16, 2020
Validation Date:
October 7, 2020
Design Pressures:
-168.5psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 43 - Composite Roof Panels
CSI Code: 07 41 23 - Wood Roof Panels
CSI Code: 07 41 63 - Fabricated Roof Panel Assemblies
Other:
-69.25 psf at 9-9-9-9 Fastener Pattern at 24 O.C.-168.5 psf at 6.5-2.5-6.5-2.5-6.5-2.5-6.5 Fastener Pattern at 12 O.C.
Notes:
Date Submitted: September 16, 2020
Date Validated: October 7, 2020
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: -69.25 psf at 9-9-9-9 Fastener Pattern at 24 O.C.-168.5 psf at 6.5-2.5-6.5-2.5-6.5-2.5-6.5 Fastener Pattern at 12 O.C.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
MICHAEL STANEK
Address:
302 4th Avenue,
Welaka, Florida 32193 USA
Welaka, Florida 32193 USA
Phone:
Listing Changes
Last Synced: 04/01/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL6095 R6 II 29GA SUPERPRO PLYWOOD

PR TECH DOCS FL6095 R6 AE 29GA SUPERPRO PLYWOOD
QR Code To This Listing