Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
6" Deep Horizontal Blade Louver, Extruded Aluminum, UL Classified, Impact & Pressure Resistant
Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Wall Louver
Evaluator:
-
Validator:
UL LLC
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
UL LLC
Specifications
Submission Date:
October 19, 2023
Validation Date:
February 8, 2024
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-200psf / +200psf
Possible CSI Codes:
CSI Code: 08 91 16 - Operable Wall Louvers
CSI Code: 07 70 00 - Roof and Wall Specialties and Accessories
CSI Code: 05 14 00 - Structural Aluminum Framing
CSI Code: 08 12 16 - Aluminum Frames
CSI Code: 07 46 19 - Steel Siding
Other:
Allowable Stress Design (ASD). Load and Size Ratings in Accordance with the Attached Table. Rated for TAS 201 Basic Impact Missile Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL35289 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood.
Notes:
Date Submitted: October 19, 2023
Date Validated: February 8, 2024
Entity: UL LLC
Compliance Method: Certification Mark or Listing
Other: Allowable Stress Design (ASD). Load and Size Ratings in Accordance with the Attached Table. Rated for TAS 201 Basic Impact Missile Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL35289 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood.