FL7395.1-R6

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:

Type M and Type PBM

Database:
Florida Product Approval
Source Link:
Description:

1. Type M and PBM, 22 gage, Min. Fy = 50 ksi, Min. Fu = 65 ksi2. Type M and PBM, 24 gage, Min. Fy = 50 ksi, Min. Fu = 65 ksi3. Type M and PBM, 26 gage, Min. Fy = 80 ksi, Min. Fu = 82 ksi

Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Siding
Evaluator:
Dennis Johnson - PE-54340
Validator:
John Southard, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
December 22, 2017
Validation Date:
February 9, 2018
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
No [FL]
Design Pressures:
-29.4psf / +32.3psf
Possible CSI Codes:
CSI Code: 07 46 19 - Steel Siding
CSI Code: 07 46 43 - Composition Siding
CSI Code: 07 46 63 - Fabricated Panel Assemblies with Siding
CSI Code: 07 46 29 - Plywood Siding
CSI Code: 07 46 33 - Plastic Siding
Other:
+32.2 / -29.4 psf at 5'-0" O.C. with fasteners at 12" O.C. (See Evaluation Report and Span Load Tables for additional design pressures)
Notes:


Date Submitted: December 22, 2017

Date Validated: February 9, 2018

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: +32.2 / -29.4 psf at 5'-0" O.C. with fasteners at 12" O.C. (See Evaluation Report and Span Load Tables for additional design pressures)

Official Site Status: Approved

Subcategory: Siding
Manufacturer Info
ACI Building Systems, LLC is a family-owned and operated company that has been providing quality metal building systems for over 40 years. Based in Terrell, Texas, ACI offers a wide range of custom-designed buildings for various applications including commercial, industrial, agricultural, and residential. They specialize in providing complete building solutions, from design and engineering to manufacturing and installation, with a focus on customer satisfaction and attention to detail. View all listings
* This manufacturer has not claimed their profile. Any logo or description displayed above has been generated by AI.
Contact Information
Representative:
Johnson Dennis
Address:
10125 Highway 6 West PO Box 1316,
Batesville, Mississippi 38606 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 04/20/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL7395 R6 II PBM INSTALLATION DETAILS
PR INSTL DOCS FL7395 R6 II PBM INSTALLATION DETAILS
PR TECH DOCS FL7395 R6 AE PBM WALL EVALUATION REPORT
PR TECH DOCS FL7395 R6 AE PBM WALL EVALUATION REPORT
QR Code To This Listing
FL7395.1-R6 Listing QR Code
Shopping Cart