FL7533.1-R7

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:

StyleGuard Double Hung

Database:
Florida Product Approval
Source Link:
Description:

StyleGuard Double Hung

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Double Hung
Evaluator:
  -  
Validator:
National Accreditation & Management Institute
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
National Accreditation & Management Institute
Specifications
Submission Date:
January 15, 2020
Validation Date:
January 23, 2020
Expiration Date:
12/31/2021
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-50psf / +50psf
Possible CSI Codes:
CSI Code: 08 60 00 - Roof Windows and Skylights
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 63 19 - Vaulted Metal-Framed Skylights
CSI Code: 08 01 64 - Operation and Maintenance of Plastic-Framed Skylights
Other:
Largest tested size for single unit is 44" x 76"Glazing material is Proglaze 2 (2 part silicon) made by Tremco.Linear extrusion was tested to ASTM D2843, D635, D1929, D638.Setting Blocks are made of Neoprene (Durometer: 85+/- 5). IGU Spacer: Alum Spacer w/ primary sealant of Polyisobutylene (PIB) & secondary sealant of structural silicone intended for fabrication of IGU.All exterior glazing above 30 ft should be tempered.
Notes:


Date Submitted: January 15, 2020

Date Validated: January 23, 2020

Entity: National Accreditation & Management Institute

Compliance Method: Certification Mark or Listing

Other: Largest tested size for single unit is 44" x 76"Glazing material is Proglaze 2 (2 part silicon) made by Tremco.Linear extrusion was tested to ASTM D2843, D635, D1929, D638.Setting Blocks are made of Neoprene (Durometer: 85+/- 5). IGU Spacer: Alum Spacer w/ primary sealant of Polyisobutylene (PIB) & secondary sealant of structural silicone intended for fabrication of IGU.All exterior glazing above 30 ft should be tempered.

Official Site Status: Approved

Subcategory: Double Hung
Contact Information
Representative:
N/A
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 03/06/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL7533 R7 C CAC NI006541.02-R8 - STYLE GUARD - DH
PR CERTIFICATE FL7533 R7 C CAC NI006541.02-R8 - STYLE GUARD - DH
PR INSTL DOCS FL7533 R7 II YKK139 SS 2015-06-24
PR INSTL DOCS FL7533 R7 II YKK139 SS 2015-06-24
PR TECH DOCS FL7533 R7 AE PER3760 SS 2015-06-25
PR TECH DOCS FL7533 R7 AE PER3760 SS 2015-06-25
QR Code To This Listing
FL7533.1-R7 Listing QR Code
Shopping Cart