FL812.1-R11

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

Armor Screen Series 2000

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

Flexible Wind Abatement / Impact Protection System

Listing Details
Category:
Impact Protection Devices
Subcategory:
Removable
Evaluator:
Gordon DiBattisto, P.E. - PE-82328
Validator:
Troy Bishop, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
October 23, 2023
Validation Date:
November 3, 2023
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-130psf / +130psf
Possible CSI Codes:
CSI Code: 26 32 23 - Wind Energy Equipment
CSI Code: 10 26 23.13 - Impact Resistant Wall Protection
CSI Code: 48 15 00 - Wind Energy Electrical Power Generation Equipment
CSI Code: 10 71 16.16 - Movable Storm Panels
CSI Code: 26 41 13 - Lightning Protection for Structures
Other:
This system is not for use in the high velocity hurricane zone (H.V.H.Z.). Glass separation is required for installations within wind zone 4 and on essential facilities. The un-breached envelope criterion is met since the system is considered 'non-porous' and remains intact under impact and air pressure loading. The system is to enclose the protected opening all around.
Notes:


Date Submitted: October 23, 2023

Date Validated: November 3, 2023

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: This system is not for use in the high velocity hurricane zone (H.V.H.Z.). Glass separation is required for installations within wind zone 4 and on essential facilities. The un-breached envelope criterion is met since the system is considered 'non-porous' and remains intact under impact and air pressure loading. The system is to enclose the protected opening all around.

Official Site Status: Approved

Subcategory: Removable
Contact Information
Representative:
Douglas Turner
Address:
2744 Hillsboro Road,
West Palm Beach, Florida 33405 USA

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 07/26/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes