Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
April 30, 2024
Validation Date:
May 6, 2024
HVHZ Approved:
Yes
Impact Resistant:
[ None ]
Design Pressures:
-159.25psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 23 - Wood Roof Panels
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 61 00 - Sheet Metal Roofing
Other:
Main Field Pressure: -71.75 psf @ 9"-9"-9"-9" fastener pattern @ 24" o.c. fastener spacing. Perimeter and Corner Pressure: 159.25 psf @ 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" fastener pattern 12" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC . For use in HVHZ Zones.
Notes:
Date Submitted: April 30, 2024
Date Validated: May 6, 2024
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Main Field Pressure: -71.75 psf @ 9"-9"-9"-9" fastener pattern @ 24" o.c. fastener spacing. Perimeter and Corner Pressure: 159.25 psf @ 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"-2.5" fastener pattern 12" o.c. fastener spacing. Install per manufacturers details and in compliance with Current FBC . For use in HVHZ Zones.