Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
September 22, 2017
Validation Date:
October 8, 2017
Expiration Date:
12/31/2021
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-60psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 23 - Wood Roof Panels
CSI Code: 07 41 43 - Composite Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 33 - Plastic Roof Panels
Other:
-60.0 psf @ 5'-0" o.c. -150.0 psf @ 2'-0" o.c. The panel is a thru-fastened structural roof panel installed over open framing in accordance with the specified loads for windward/leeward wind pressures. Design Engineer must evaluate the panel attachment to substrate for fastener pullout/pullover per AISI Specifications. Install per manufacturer erection details and RAS 133. The use of this panel for shear roof application is outside the scope of this product approval.HVHZ
Notes:
Date Submitted: September 22, 2017
Date Validated: October 8, 2017
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: -60.0 psf @ 5'-0" o.c. -150.0 psf @ 2'-0" o.c. The panel is a thru-fastened structural roof panel installed over open framing in accordance with the specified loads for windward/leeward wind pressures. Design Engineer must evaluate the panel attachment to substrate for fastener pullout/pullover per AISI Specifications. Install per manufacturer erection details and RAS 133. The use of this panel for shear roof application is outside the scope of this product approval.HVHZ