FL9329.1-R4
Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:
26 Ga. ¾ Rib Roof Panel
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
26 Ga. ¾ Rib Roof Panel over 1x4 SYP Wood Purlins over 15/32" APA plywood
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Locke Bowden - PE-49704
Validator:
Zachary R. Priest, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 8, 2017
Validation Date:
October 11, 2017
Design Pressures:
-164.25psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 23 - Wood Roof Panels
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 41 63 - Fabricated Roof Panel Assemblies
Other:
-106.75 PSF @ 9"-9"-9"-9" fastener pattern @ 24" O.C. fastener spacing. -164.25 PSF @ 9"-9"-9"-9" fastener pattern @ 12" O.C. fastener spacing. Install per manufacturers details and in compliance with FBC 2017. For use in HVHZ Zone.
Notes:
Date Submitted: October 8, 2017
Date Validated: October 11, 2017
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: -106.75 PSF @ 9"-9"-9"-9" fastener pattern @ 24" O.C. fastener spacing. -164.25 PSF @ 9"-9"-9"-9" fastener pattern @ 12" O.C. fastener spacing. Install per manufacturers details and in compliance with FBC 2017. For use in HVHZ Zone.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
N/A
Website:
Listing Changes
Last Synced: 03/14/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL9329 R4 II FL9329 R4 AE FL 9329 FREEPORT METALS FINAL-CRSS

PR TECH DOCS FL9329 R4 AE FL9329 R4 AE FL 9329 FREEPORT METALS FINAL-CRSS
QR Code To This Listing