ITK-26832

Report Status
Approved
Manufacturer:
Database:
Intertek
Source Link:
Description:

Concept Frames 3 Hour Mineral Core Steel Fire Doors

Listing Details
Category:
Doors
Specifications
Possible CSI Codes:
CSI Code: 08 11 69.13 - Steel Storm Doors and Frames
CSI Code: 08 11 00 - Metal Doors and Frames
CSI Code: 08 11 69 - Metal Storm Doors and Frames
CSI Code: 08 10 00 - Doors and Frames
CSI Code: 08 11 13 - Hollow Metal Doors and Frames
Notes:
Criteria: NFPA 252 (1995)
Criteria: ASTM E152-81a
Criteria: UL 10(c) (1998)
Criteria: UBC 7-2 (1997)
Criteria: UBC 7-2 (1994)
Criteria: UL 10(b) (1997)
Criteria: CAN4 S104 (1985)
Criteria: UL 10(b) 2008 (R2009)
Criteria: UL 10(c) (2009)
Criteria: CAN / ULC S104 (2010)
CSI Code: 08 11 00 Metal Doors and Frames
CSI Code: 08 11 13 Hollow Metal Doors and Frames
Fire Resistance: 3 Hour Neutral Pressure
Fire Resistance: 3 Hour PP Category A Door
Intertek Services: Certification
Listed or Inspected: LISTED
Listing Section: CATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID: 26832
Swing: Single Swing
Swing: Standard Pairs
Swing: Double Egress
Temperature Rise: @ 30 Min = 250° F MAX Where Lites Do Not Exceed 100 IN2
Temperature Rise: @ 60 Min Does Not Exceed 450° F (250° C)
Standards
ASTM E152-81a; CAN / ULC S104 (2010); CAN4 S104 (1985); NFPA 252 (1995); UBC 7-2 (1994); UBC 7-2 (1997); UL 10(b) (1997); UL 10(b) 2008 (R2009); UL 10(c) (1998); UL 10(c) (2009)

Contact Information
Representative:
N/A
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 10/13/2024
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
LISTING REPORT-26832
LISTING REPORT-26832
QR Code To This Listing
ITK-26832 Listing QR Code
Shopping Cart