Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Fixed (8300) 52.125" x 75" Insulated Glass (5/16 PVB Lam in - 3/16 Annealed out)
Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Fixed
Evaluator:
-
Validator:
National Accreditation & Management Institute
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
National Accreditation & Management Institute
Specifications
Submission Date:
August 15, 2017
Validation Date:
August 15, 2017
Expiration Date:
12/31/2021
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-55psf / +55psf
Possible CSI Codes:
CSI Code: 04 23 19 - Glass Unit Masonry Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 60 00 - Roof Windows and Skylights
CSI Code: 08 62 00 - Unit Skylights
CSI Code: 08 01 60 - Operation and Maintenance of Skylights and Roof Windows
Other:
Windows with insulated glass units wider than 36" require setting blocks. These windows do not meet small missile impact wind-borne requirements as required by FBC, section 2411.3.3.7 when the exterior lite is annealed. These windows meet small missile impact wind-borne protection requirements as required by FBC, section 2411.3.3.7 when the exterior lite is tempered. Miami-Dade NOAs: Quanex Building Products, Inc PVC (12-1017.02 and 13-0425.15), Dupont PVB Interlayer(13-0129.27).
Notes:
Date Submitted: August 15, 2017
Date Validated: August 15, 2017
Entity: National Accreditation & Management Institute
Compliance Method: Certification Mark or Listing
Other: Windows with insulated glass units wider than 36" require setting blocks. These windows do not meet small missile impact wind-borne requirements as required by FBC, section 2411.3.3.7 when the exterior lite is annealed. These windows meet small missile impact wind-borne protection requirements as required by FBC, section 2411.3.3.7 when the exterior lite is tempered. Miami-Dade NOAs: Quanex Building Products, Inc PVC (12-1017.02 and 13-0425.15), Dupont PVB Interlayer(13-0129.27).
Official Site Status: Approved
Subcategory: Fixed
Contact Information
Representative:
Rylee Fricks
Address: