Max 16.375" wide, nom 0.032" thick (min.) aluminum concealed fastener roof panel over min 15/32" thick plywood deck or 7/16" thick OSB.
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Bala Sockalingam - PE-62240
Validator:
Yoosef Lavi, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
October 10, 2020
Validation Date:
October 12, 2020
HVHZ Approved:
No
Impact Resistant:
[ None ]
Design Pressures:
-93.5psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 05 33 23 - Aluminum Roof Decking
CSI Code: 07 61 00 - Sheet Metal Roofing
Other:
Uplift load of 22.5 psf at fastener spacing of 18.5" o.c. and 86.0 psf at fastener spacing of 4.63" o.c. in 15/32" plywood or 7/16" OSB. Uplift load of 93.5 psf at fastener spacing of 4.63" o.c. with adhesive in 15/32" plywood.
Notes:
Date Submitted: October 10, 2020
Date Validated: October 12, 2020
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Uplift load of 22.5 psf at fastener spacing of 18.5" o.c. and 86.0 psf at fastener spacing of 4.63" o.c. in 15/32" plywood or 7/16" OSB. Uplift load of 93.5 psf at fastener spacing of 4.63" o.c. with adhesive in 15/32" plywood.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Randy Blake
Address:
PO Box 229, Fayetteville, North Carolina 28302 United States