Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Max 18" wide, min 24 ga., snap-lock standing seam metal panel over 15/32" thick plywood
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Bala Sockalingam - PE-62240
Validator:
Yoosef Lavi, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
August 23, 2017
Validation Date:
August 28, 2017
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
[ None ]
Design Pressures:
-93.5psf / +0psf
Possible CSI Codes:
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 71 00 - Roof Specialties
Other:
Uplift load of 39.8 psf @ clip spacing of 36" o.c. and 78.6 psf @ clip spacing of 8" o.c with felt.Uplift load of 93.5 psf @ clip spacing of 12" o.c. with self-adhering membrane.
Notes:
Date Submitted: August 23, 2017
Date Validated: August 28, 2017
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Uplift load of 39.8 psf @ clip spacing of 36" o.c. and 78.6 psf @ clip spacing of 8" o.c with felt.Uplift load of 93.5 psf @ clip spacing of 12" o.c. with self-adhering membrane.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Randy Blake
Address: