FL30502.1-R1
Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Revision
Folio:
Model:
Aluminum ML200
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Max 18" wide, nom 0.032" thick (min.) aluminum standing seam panel over min 15/32" thick plywood deck
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Bala Sockalingam - PE-62240
Validator:
Yoosef Lavi, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 13, 2020
Validation Date:
October 17, 2020
Design Pressures:
-146.4psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 61 19 - Flat Seam Sheet Metal Roofing
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
Other:
Uplift load of 63.5 psf at clip spacing of 24" o.c. and 146.4 psf at clip spacing of 6" o.c.
Notes:
Date Submitted: October 13, 2020
Date Validated: October 17, 2020
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Uplift load of 63.5 psf at clip spacing of 24" o.c. and 146.4 psf at clip spacing of 6" o.c.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Randy Blake
Address:
PO Box 229,
Fayetteville, North Carolina 28302 United States
Fayetteville, North Carolina 28302 United States
Phone:
Website: