FL40264.5-R0
Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
New
Folio:
Model:
Image II
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Min. 26 ga., 16" wide concealed fastened roof panel over min. 15/32 thick plywood deck or 7/16" thick OSB.
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Bala Sockalingam - PE-62240
Validator:
Yoosef Lavi, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
November 24, 2021
Validation Date:
November 29, 2021
Design Pressures:
-116psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 05 31 23 - Steel Roof Decking
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 61 00 - Sheet Metal Roofing
Other:
Uplift load of 20.8 psf at fastener spacing of 24" o.c., 63.5 psf at fastener spacing of 6" o.c., 86.6 psf at fastener spacing of 6" o.c. with sidelap adhesive and 116 psf at fastener spacing of 6" o.c. with support strap & adhesive.
Notes:
Date Submitted: November 24, 2021
Date Validated: November 29, 2021
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Uplift load of 20.8 psf at fastener spacing of 24" o.c., 63.5 psf at fastener spacing of 6" o.c., 86.6 psf at fastener spacing of 6" o.c. with sidelap adhesive and 116 psf at fastener spacing of 6" o.c. with support strap & adhesive.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
N/A
Listing Changes
Last Synced: 11/21/2026
Change Log effective March 1st 2023